15.2% increase in output due to

reliable reduction in cooling time

Smart Plastify has replaced the fixed cooling time with state-based demolding approval using Moldsonics.

The component is opened when it is physically ready—not only after a safety buffer expires.

   Cooling time

   30 s → 14–15 s

 

   Cycle Time

   103.8 s → 88 s

 

   Output

   +15,2%

 

CHALLENGE

Cooling time is the parameter that no one touches anymore.

It is set with a safety margin during sample approval. Years later, the production department continues to pay for this margin—because reducing it seems risky: delays, scrap, and customer complaints.

 

SOLUTION

Moldsonics detects when the part is truly ready.

The sensor detects the physical moment of demolding in the mold. The cooling time is controlled based on the current state; the fixed time remains only as a safety limit.

 

Measured during production.

 Before

   – Fixed cooling time: 30 s

   – Cycle time: 103.8 s

   – Hidden safety buffer

   – Reduced cooling time = risk

 Afterward

   ✓ State-based cooling time: 15 s

   ✓ Cycle time: 88 s

   ✓ Defined safety window

   ✓ Reduced cooling time = controlled increase in output

+15.2% increase in output per machine

THIS IS RELEVANT WHEN

They suspect that there is a hidden cooling buffer.

 

   – The cooling time was set at the time of sampling and has not been adjusted since then.

   – Thick-walled parts limit your cycle time.

   – Operators avoid shortening the cooling time because the risk of scrap is unclear.

   – Variations in materials or processes require safety margins.

Learn how fixed cooling times in production were replaced by condition-based cooling.

Download the Smart Plastify use case, including measurement data, setup, and results: The cycle time was reduced from 103.8 s to 88 s.

Moldsonics Logo

Moldsonics GmbH
Hafenstraße 47-51
4020 Linz, Austria

info@moldsonics.at

Legal Notice

Privacy Policy

Terms and Conditions

Copyright 2026: Moldsonics GmbH
All rights reserved

partner-logo-kc-cluster-sw